250V LB series

Description

Features :Radial leaded devices,High voltage surge capabilities,UL94 V-0 insulating material, Agency Recognition: UL、CSA,Lead-free and compliant with the European Union RoHS Directive 2011/65/EU.


IH=Hold current: maximum current at which the device will not trip at 25℃ still air.

IT=Trip current: minimum current at which the device will always trip at 25℃ still air.

Vmax=Maximum voltage device can withstand without damage at rated current.

Imax=Maximum fault current device can withstand without damage at rated voltage. 

Max Time-to-trip=Maximum time to trip(s) at assigned current.

Pd max=Maximum power dissipation: maximum power dissipated by the device when in state air environment.

Rmin=Minimum device resistance at 25℃ prior to tripping.

Rmax=Maximum device resistance at 25℃ prior to tripping.

R1max=Maximum device resistance at 25℃, of device one hour after being tripped the first time.

Reset
Type Part No. IH(A) IT(A) Max Trip Current(A) Max Trip Time(s) Vmax(V) Imax(A) Pdtyp(W) Rmin(Ω) Rmax(Ω) R1max(Ω) Data sheet