中文
homeApplication
90-264V AC

 

Solution Circuit Diagram

 

 

Application Environment

1.High frequent thunderstorm weather

2.Hazardous consequences after the power supply stricken by lightning with

    expensive maintenance cost

3.High surge protection level required

 

Solution Descriptions

1.Use GDT and MOV devices for protection to achieve bleeder current effect.

2.Meet the IEC61000-4-5 surge test standard.

3.Can pass the surge level IEC 61000-4-5 1.2/50μs-8/20μs 2Ω DM:6KV-3KA  CM:10KV-5KA  test.

 

Protection Components for Recommendation

 

 

wayon

Part Number

DC breakdown

Voltage 

Tolerance

of Vs 

Impulse

Spark-over 

Impulse

Discharge

Current

Capacitance

at 1 MHz

Package

Product link

 100V/S (V)

(V)

1KV/μs (V)

8/20 μs (KA)

(PF)

GDTA2RD8-600N

600±20%

720

1000

10

<1.5

 Ø8.0×T6.0

 

wayon

Part Number

VAC

VDC

VBR

VC@1A

IPP

Capacitance

at 1 MHz

Size

Product link

(V)

(V)

1KV/μs (V)

8/20 μs (KA)

(PF)

20D681K

40

56

68

135

20

11200

 Ø20

 

 

Application Solution PDF File

Related application information

Recommended related industries